Figure 146 on – Nortel Networks Circuit Card User Manual

Page 637

Advertising
background image

NT8D15 E&M Trunk card

Page 637 of 906

Circuit Card

Description and Installation

Figure 146
4-wire DX signaling

Tip B

T1

J3

J5

T2 (Note 2)

Ring B

a

b

Tip A

Ring A

a

b

Distant circuit

electromechanical (may also be

Succession 1000M, Succession

1000, or Meridian 1)

Local system circuit

Ð

48V

Ð

48V

4

8

553-AAA1151

1100

(Note 1)

K1

R

C

R

eq

13

0Ω

13

0Ω

K1

R

State of

trunk

detector

13

0Ω

600

1.21k

(Note 4)

1.21k

R

C

R

B

R

A

R

F

75

0Ω

400

600

370

370

370

250

See Note 5

See

Note 5

6µF

4µF

4µF

Balancing

resistance

(see Note 3)

370

1k

R

A

or

D1

B1

A1

R

E

External

loop

(5k

max.)

See

Note 5

Note 1:

The equivalent bridge circuit resistance as seen from distant trunk during the signaling is 1250 ±125 Ohms.

Note 2:

T1 and T2 resistance is 47 Ohms for 600 Ohm termination option.

Note 3:

Compute total balancing resistance as follows (note that in some new DX circuits, a 1260 Ohm resistor is permanently wired in s

eries

with the selectable resistance). Total balancing R = external loop resistance + 0.5 x T1 resistance + 0.5 x T2 resistance + [(R

A

+ R

D

) if not shorte

d

out] + R

eq

. Resistance of transformers at electromechanical end is low and can be ignored. "External loop resistance" is defined as 1/2 t

he loop

resistance of one cable pair.

Note 4:

If the external loop is >2500 Ohms, the loop adjustment resistors R

A

and R

B

are shorted out. If the external loop is <2500 Ohms, R

A

an

d

R

B

are in the circuit.

When the system is connected to another Meridian 1 or pulse and external loop resistance is <2500 Ohms, the loop

adjustment resistors must be shorted in one machine. If the external loop is >2500 Ohms, the loop adjustment resistors must be

shorted out in

both machines.

Note 5:

When the system is connected to an electromechanical trunk using 4-wire operation, a 4µF capacitor must be connected from the A

1 to

B1 lead at each end of the trunk. (These may already be installed.) It is also recommended that a 6µF capacitor be connected in

series with the

balancing resistance.