Nortel Networks Circuit Card User Manual
Page 67

Overview
Page 67 of 906
Circuit Card
Description and Installation
signaling data to the line card, it is sent as a 24-bit word divided among 24
successive DS-30X frames.
DS-30Y network loops extend between controller cards and superloop
network cards in the common equipment, and function in a manner similar to
DS-30X loops. See Figure 13 on
.
Essentially, a DS-30Y loop carries the PCM timeslot traffic of a DS-30X
loop. Four DS-30Y network loops form a superloop with a capacity of 128
channels (120 usable timeslots).
See Communication Server 1000M and Meridian 1: Large System Planning
and Engineering (553-3021-120) for more information on superloops.
Card LAN link
Maintenance communication is the exchange of control and status data
between IPE line or trunk cards and the CE CPU by way of the NT8D01
Controller Card. Maintenance data is transported via the card LAN link. This
Figure 12
DS-30X loop data format
29
W0B7
W31DV
DS-30X loop
data words
Frame
sync
Frame sync
DS-30X loop
data bits
5.12 MHz
2.56 MHz
SB = SIGNALING BIT DV = DATA VALID
30
31
0
1
2
3
4
W0B6
W0B5
W0B4
W0B3
W0B2
W0B1
W0B0
W0SB W0DV
W1B7