Overview

Page 67 of 906

Circuit Card

Description and Installation

signaling data to the line card, it is sent as a 24-bit word divided among 24
successive DS-30X frames.

DS-30Y network loops extend between controller cards and superloop
network cards in the common equipment, and function in a manner similar to
DS-30X loops. See Figure 13 on

page 68

.

Essentially, a DS-30Y loop carries the PCM timeslot traffic of a DS-30X
loop. Four DS-30Y network loops form a superloop with a capacity of 128
channels (120 usable timeslots).

See Communication Server 1000M and Meridian 1: Large System Planning
and Engineering
(553-3021-120) for more information on superloops.

Card LAN link

Maintenance communication is the exchange of control and status data
between IPE line or trunk cards and the CE CPU by way of the NT8D01
Controller Card. Maintenance data is transported via the card LAN link. This

Figure 12
DS-30X loop data format

29

W0B7

W31DV

DS-30X loop

data words

Frame

sync

Frame sync

DS-30X loop

data bits

5.12 MHz

2.56 MHz

SB = SIGNALING BIT DV = DATA VALID

30

31

0

1

2

3

4

W0B6

W0B5

W0B4

W0B3

W0B2

W0B1

W0B0

W0SB W0DV

W1B7

553-6151