Environmental, Reliability, Installing the data access card – Nortel Networks Circuit Card User Manual

Page 505: Cabinet system

Advertising
background image

NT7D16 Data Access card

Page 505 of 906

Circuit Card

Description and Installation

Environmental

The DAC functions fully when operating within the following specified
conditions. See Table 166.

Reliability

The DAC has a predicted mean time between failure (MTBF) of 8 years at
45 degrees Celsius. The mean time to repair (MTTR) is 1 hour.

Installing the Data Access card

Cabinet system

The DAC is fully supported in any card slot in either the main or expansion
cabinet without any hardware modification. Insert the DAC into any available
card slot and secure it in place using the locklatches.

To cable out the DAC, run a standard 25-pair cable to the cross connect, or
use one of the following breakout cables in conjunction with an Amphenol
50-pin female-to-female gender converter:

QCAD318A50-pin Amphenol to 6 female DB25 connectors

QCAD319A50-pin Amphenol to 6 male DB25 connectors

Note: For Cabinet system, the format to be used in response to the “TN”
prompt must be one of the following:

CC 00 00 UUCC - Card Slot

or

CC UUUU - Unit Number

Table 166
DAC environmental specifications

Specification

Operating

Storage

Ambient temperature

0 to 60 degrees C

40 to 70 degrees C

Humidity

5% to 95%

5% to 95%

Advertising