Configuring the qsdi card – Nortel Networks Circuit Card User Manual

Page 876

Advertising
background image

Page 876 of 906

QPC841 Quad Serial Data Interface card

553-3001-211 Standard 3.00 August 2005

Configuring the QSDI card

Configuring the QSDI card consists of setting these option switches for each
serial port:

Port address

Baud rate

DTE/DCE mode

Figure 189 on

page 880

shows the location of the option switches on the

QSDI card. Instructions for setting these switches are in the section that
follows.

Address switch settings

Table 275 on

page 877

lists the address switch settings for the QPC841 Quad

Serial Data Interface card. The address select jumpers and logic on the card
address the UARTs using two pairs of addresses: 0 and 1, 2 and 3, through 15
and 16. The pairs do not need to be consecutive. Switch SW14 is used to

19

GND

Ground

Ground

21

CD

Carrier detect (Note 1

Carrier detect (not used)

22

DTR

Data terminal ready

Data terminal ready (Note 2))

Note 1: In DTE mode, the signals CD, DSR, and CTS are tied to +12 volts (through a resistor)
to indicate that the QSDI port is always ready to transmit and receive data.

Note 2: In DCE mode, the signals DTR and RTS are tied to +12 volts (through a resistor) to
indicate that the QSDI port is always ready to transmit and receive data.

Table 274
Connector J2 pin assignments (Part 2 of 2)

Pin

Number

Port

Signal

Purpose in DTE mode

Purpose in DCE mode