Overview

Page 63 of 906

Circuit Card

Description and Installation

Operation

This section describes how trunk cards fit into the CS 1000S, CS 1000M, and
Meridian 1 architecture, the buses that carry signals to and from the trunk
cards, and how they connect to terminal equipment. See Table 8 for IPE
parameters.

Host interface bus

Cards based on the IPE bus have a built-in microcontroller. The IPE
microcontroller is used for the following:

to perform local diagnostics (self-test)

to configure the card according to instructions issued by the system
processor

to report back to the system processor information such as card
identification (type, vintage, and serial number), firmware version, and
programmed configuration status.

Intelligent Peripheral Equipment

IPE trunk cards all have a similar architecture. Figure 11 on

page 64

shows a

typical IPE trunk card architecture. The various trunk cards differ only in the
number and types of trunk interface units.

Table 8
Differences between IPE parameters

Parameter

IPE

Card Dimensions

31.75 x 25.4 x 2.2 cm. (12.5 x10.0 x 0.875 in.)

Network Interface

DS-30X Loops

Communication Interface

card LAN Link

Microcontroller

8031

Peripheral Interface card

NT8D01 Controller card

Network Interface card

NT8D04 Superloop Network card

Modules

NT8D37 IPE module

Advertising