Qpc775 clock controller card – Nortel Networks Circuit Card User Manual

Page 152

Advertising
background image

Page 152 of 906

Option settings

553-3001-211 Standard 3.00 August 2005

QPC775 Clock Controller card

Tables 58 and 59 give option settings for the QPC775 Clock Controller
card.

Table 58
QPC775 (before vintage E) switch settings

System

SW2

SW3

SW4

1

2

3

4

1

2

3

4

1

2

3

4

CS 1000M MG

off

off

off

off

off

off

off

off

on

on

on

on

CS 1000M SG

on

on

on

on

off

off

off

off

on

on

on

on

Table 59
QPC775 vintage E switch settings

System

SW1

SW2

SW4

1

2

3

4

1

2

3

4

1

2

3

4

CS 1000M SG

on

on

on

on

off

off

off

off

off

on

*

*

CS 1000M MG

on

off

off

off

off

off

off

off

**

on

*

*

*Cable length between the J3
faceplate connectors:

0–4.3 m (0–14 ft)

off

off

4.6–6.1 m (15–20 ft)

off

on

6.4–10.1 m (21–33 ft)

on

off

10.4–15.2 m (34–50 ft)

on

on

*

If there is only one Clock Controller card in the system, set to OFF. If there are two Clock Controller
cards, determine the total cable length between the J3 connectors (no single cable can exceed 25 ft.)
and set these two switch positions for this cable length, as shown above. The maximum total (combined)
length is 50 ft. Set the switches on both cards to the same settings.

** Set to ON for clock controller 0. Set to OFF for clock controller 1.

Advertising