See “set clearing” on – Nortel Networks Circuit Card User Manual

Page 294

Advertising
background image

Page 294 of 906

NT5D33 and NT5D34 Lineside E1 Interface cards

553-3001-211 Standard 3.00 August 2005

Note: If the duration period set is too long, the LEI card is slow to return
to service automatically even when the carrier is no longer experiencing
errors. The CLEAR ALARM (C A) command has to be entered
manually to restore service promptly. To avoid this, an alarm’s duration
period is normally set to 10 seconds.

Set Clearing

The SET CLEARING (S C) command allows self-clearing of alarms by
responding to the question: Enable Self Clearing? (YES or NO). If YES is
chosen (the factory default setting), the system automatically clears (resets)
alarms after the alarm condition is no longer detected. Choosing the NO
option causes the system to continue the alarm condition until the Clear
Alarm (C A)
command is entered. Line processing and yellow alarm
indication to the CPE terminates as soon as the alarm condition clears, even
if self-clearing is disabled.

Set Simple

The SET SIMPLE command controls call tear-down signaling when the
far-end disconnects from a call.

AL2 Threshold

Sets the allowable bit errors per second (from 3 to
9) before alarm level 2 is activated. Factory
default is 10

-5

.

AL2 Duration

Sets the duration in seconds (from 1 to 3,600
seconds) that alarm level 2 is activated. Factory
default is 10 seconds.

Frame Slip
Threshold

Sets the allowable frame slips per time period
(from 1 to 255) before alarm level 2 is activated.
Factory default is 5.

Frame Slip Duration

Sets the duration in hours (from 1 to 24) that the
frame slips are counted. After this time period, the
counter is reset to 0. Factory default is 2 hours.

Table 107

Set alarm options

(Part 2 of 2)

Option

Description

Advertising