Nortel Networks Circuit Card User Manual

Page 458

Advertising
background image

Page 458 of 906

NT7D16 Data Access card

553-3001-211 Standard 3.00 August 2005

unless the DTR lead is driven ON by the terminal. Any terminal that drives
the DTR lead ON can be used with this mode (such as VT100 or VT102).

The DAC drives CTS, DSR, and DCD ON, except when a call is dropped or
when control—Z is entered during the idle state. In this case, the DAC drives
those leads OFF for 0.2 seconds and then ON. When the DTR lead is driven
OFF by the terminal, the DAC does not execute autobaud, nor will it respond
to any command.

Note: If the PBDO parameter in LD 11 is ON, then Make Set Busy will
be activated when DTR is driven OFF for more than five seconds.

Programing DAC for mode 12 in service change LD 11

The DAC must be configured as R232 or R422 since Autodial, Speed Call,
and Display commands are likely to be used.

Figure 94
DAC to Terminal connectivity

pin 2
pin 3
pin 5
pin 6
pin 7
pin 8
pin 20
pin 22

TX
RX
CTS
DSR
GND
DCD
DTR
RI

Terminal (DTE)

DAC (DCE)

RS- 232 leads

>>>

<<<
<<<

<<<

<<<

<<<

>>>

not required
for mode 14

553-5220