Large system and cs 1000m hg upgrade – Nortel Networks Circuit Card User Manual

Page 524

Advertising
background image

Page 524 of 906

NT7D16 Data Access card

553-3001-211 Standard 3.00 August 2005

Large System and CS 1000M HG upgrade

The DAC can be installed directly into slots 0, 4, 8, and 12 with no cabling
changes. If other slots are required, the upgrade must be made. Follow this
procedure to upgrade your cabling. You can upgrade the cabling
segment-by-segment, or the entire module at one time.

Note 1: Four NT8D81AA cable/filter assemblies are required to
upgrade the entire module, one assembly per segment.

Note 2: Cables are designated by the letter of the I/O panel cutout where
the 50-pin cable connector is attached. The 20-pin connectors are labeled
1, 2, and 3.

Note 3: The locations for the cable connectors are designated by the slot
number (L0-L9), and the shroud row (1, 2, and 3).

Segment 0

1

Leave cable A as is in slot L0.

2

Move cable end B-3 to L1-3.

3

Remove cable C from the backplane and connect ends C-1, C-2, and C-3
to L2-1, L2-2, and L2-3.

4

Add cable D to the I/O panel by connecting ends D-1, D-2, and D-3 to
L3-1, L3-2, and L3-3.

Segment 1

1

Leave cable E as is in slot L4.

2

Move cable end F-3 to L5-3.

3

Remove cable G from the backplane and connect ends G-1, G-2, and G-3
to L6-1, L6-2, and L6-3.

4

Add cable H to the I/O panel by connecting ends H-1, H-2, and H-3 to
L7-1, L7-2, and L7-3.

Advertising