See table 193 on, For t – Nortel Networks Circuit Card User Manual

Page 621

Advertising
background image

NT8D14 Universal Trunk card

Page 621 of 906

Circuit Card

Description and Installation

Table 193
Trunk types – termination impedance and balance network (NT8D14BA, NT8D14BB)

Trunk types

Terminating

impedance

(Note 1)

Balance network for loop lengths (Note 2)

0–915 m

(0–3000 ft)

915–1524 m

(3000–5000 ft)

> 1524 m

(> 5000 ft)

CO/FX/WATS

600 or 900
ohms

600 ohms

3COM

3CM2

2-way TIE (LDR)

600 or 900
ohms

600 ohms

3COM

3CM2

2-way TIE (OAID)

600 or 900
ohms

600 ohms

3COM

3CM2

DID (loop length
< 600 ohms)

600 or 900
ohms

600 ohms

3COM

3CM2

DID (loop length
Š 600 ohms)

600 or 900
ohms

600 ohms

N/A

3CM2

RAN: continuous
operation mode

600 or 900
ohms

600 or 900 ohms

N/A

N/A

Paging

600 ohms

600 ohms

N/A

N/A

Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and
should match the nominal impedance of the connecting equipment.

Note 2: The balance network of each trunk unit is software selectable between resistive 600 or
900 ohms or 3COM and jumper selectable between 3COM and 3CM2. Jumper selection for
3COM/3CM2 restriction does not apply to NT8D14BB.