NT1R20 Off-Premise Station Analog Line card

553-3001-211 Standard 3.00 August 2005

Configuring the OPS analog line card

The line type, terminating impedance, and balance network configuration for
each unit on the card is selected by software service change entries at the
system terminal and by jumper strap settings on the card.

Jumper strap settings

Each line interface unit on the card is equipped with two jumper blocks that
are used to select the proper loop current depending upon loop length. See
Table 71.

For units connected to loops of 460 to 2300 ohms, both jumper blocks for that
unit must have jumper blocks installed. For loops that are 460 ohms or less,
jumper blocks are not installed. Figure 24 on

page 176

shows the location of

the jumper blocks on the OPS analog line card.

Table 71
OPS analog line card – configuration (Part 1 of 2)

Application

On-premise station (ONS)

Off-premise station (OPS)

Class of Service
(CLS) (Note 1)

ONP

OPX

Loop resistance
(ohms)

0–460

0–2300 (Note 2)

Jumper strap
setting (Note 6)

Both JX.0 and JX.1
off

Both JX.0 and JX.1
off

Both JX.0 and JX.1
on

Loop loss (dB)
(Note 3)

0–1.5

>0–3.0

>2.5–3.0

0–1.5

>1.5–2.5

>2.5–4.5

>4.5–15

TIMP
(Notes 1, 4)

600
ohms

600
ohms

600
ohms

600
ohms

600
ohms

600
ohms

600
ohms

BIMP
(Notes 1, 4)

600
ohms

3COM

3CM2

600
ohms

3COM

3CM2

3CM2