NT8D41AA Serial Data Interface Paddle Board

Page 677 of 906

Circuit Card

Description and Installation

Software service changes

Once the NT8D41 SDI paddle board has been installed in the system, the
system software needs to be configured to recognize it. This is done using the
Configuration Record program LD 17. Instructions for running the
Configuration Record program are found in Software Input/Output:
Administration
(553-3001-311).

Some of the prompts that are commonly used when running the Configuration
Record program LD 17, are shown in “LD 17 – Serial port configuration
parameters.” on

page 677

. These parameters must be set for each port if both

ports are being used.

LD 17 – Serial port configuration parameters.

Prompt

Response

Description

REQ:

CHG

Change configuration

TYPE:

CFN

Configuration type

IOTB

YES

Change input/output devices

ADAN

NEW TTY x

NEW PRT x

Define a new system terminal (printer) port as device x, where
x = 0 to 15.

CDNO

1–16

Use the SDI paddle board number to keep track of all ports.

DENS

DDEN

Double density SDI paddle board

USER

xxx

Enter the user of port x. The values that can be entered
depend on the software being used. See the Software Input/
Output: Administration
(553-3001-311) for details.

XSM

(NO) YES

Port is used for the system monitor.