Nortel Networks Circuit Card User Manual
Page 289

NT5D33 and NT5D34 Lineside E1 Interface cards
Page 289 of 906
Circuit Card
Description and Installation
D S(P)
Display Status. Displays carrier status, including alarm state and, if
active, alarm level. (Momentarily stop the scrolling display by typing P.
Continue scrolling by typing any other key.)
H or ?
Help. Displays the Help screen.
L
Login. Logs into the MMI terminal in a single-LEI system.
Lxx
Login. Logs into the MMI terminal in a daisy-chained system, where xx
represents the address of the card to be configured.
Q
Quit. Logs out of the MMI terminal.
Note: If it is a daisy-chained system, be certain to log out when
finished with configuration. In a daisy-chained system, only one card
may occupy the bus at a given time and all other LEIs will be unable to
notify the MMI of alarms unless logged-out of configuration mode.
S A
Set Alarm. Sets alarm parameters, such as the allowable bit-errors per
second, threshold, and alarm duration.
S C
Set Clearing. Sets the alarm self-clearing function, ”enable” or
”disable.”
S D
Set Date. Sets the date or verifies the current date.
S M
Set Mode. Sets the A/B Bits mode.
S S
Set Simple. Sets whether or not the LEI waits for the terminal
equipment to return an idle-state message before returning the channel
to idle at call disconnect from the far-end.
S T
Set Time. Sets the time or verifies current time.
T
Test. Initiates the E1 carrier test function. To terminate a test
in-process, enter the STOP TEST command at any time.
Table 105
MMI commands and command sets (Part 2 of 2)
Command
Description