NT5D97 Dual-port DTI2/PRI2 card

Page 343 of 906

Circuit Card

Description and Installation

Trunk interface switches for NT5D97AA/AB

Impedance level and unit mode

The S9/S15 switch selects the impedance level and loop operation mode on
DEI2 OR PRI2. Refer to Table 122.

Transmission mode

A per-trunk switch (S4/S10) provides selection of the digital trunk interface
type. Refer to Table 123.

Line build out

A per-trunk set of three switches (S5/S11, S6/S12 and S7/S13) provides the
dB value for the line build out. Refer to Table 124 on

page 344

.

Table 122
Impedance level and loop mode switch settings

Switch

Description

S9/S15 Switch Setting

1

Impedance level

OFF - 120 ohm
ON - 75 ohm

2

Spare

X

3

Spare

X

4

Unit mode

OFF - Loop operates in the DTI2 mode
ON - Loop operates in the PRI2 mode

Table 123
Impedance level and loop mode switch settings

Description

S4/S10 switch settings

E1

OFF