Trunk interface switches for nt5d97aa/ab – Nortel Networks Circuit Card User Manual
Page 343

NT5D97 Dual-port DTI2/PRI2 card
Page 343 of 906
Circuit Card
Description and Installation
Trunk interface switches for NT5D97AA/AB
Impedance level and unit mode
The S9/S15 switch selects the impedance level and loop operation mode on
DEI2 OR PRI2. Refer to Table 122.
Transmission mode
A per-trunk switch (S4/S10) provides selection of the digital trunk interface
type. Refer to Table 123.
Line build out
A per-trunk set of three switches (S5/S11, S6/S12 and S7/S13) provides the
dB value for the line build out. Refer to Table 124 on
.
Table 122
Impedance level and loop mode switch settings
Switch
Description
S9/S15 Switch Setting
1
Impedance level
OFF - 120 ohm
ON - 75 ohm
2
Spare
X
3
Spare
X
4
Unit mode
OFF - Loop operates in the DTI2 mode
ON - Loop operates in the PRI2 mode
Table 123
Impedance level and loop mode switch settings
Description
S4/S10 switch settings
E1
OFF
Not used