YASKAWA TM.iQp.02 iQpump Drive Programming Manual

157

Figure 1.119

Figure 124

The maximum compensation at Maximum Output Frequency (E1-04) is specified by programming the Maximum Friction Increase at

Maximum Frequency (P3-14).

The Maximum Friction Increase at Maximum Frequency (P3-14) works in conjunction with the Friction Compensation Start Frequency

(P3-13). The units for this parameter are determined by the System Units (P1-02).

Note: This function is only active when the Pump Mode (P1-01) is set to 0.

Example:

If P3-13 = 30.0 Hz, P3-14 = 10.0 PSI, Output Frequency = 45.0 Hz, and Maximum Frequency = 60 Hz, then:

Setpoint Increase = 5.0 PSI

(45.0 - 30.0 Hz) x (10 PSI / (60.0-30.0 Hz)) = 5.0 PSI

OUTPUT

FREQUENCY

P3-13

Time

SET-POINT

P3-14

FMAX

Friction

Compensation

P3-13

Advertising