Monitor data – Yaskawa iQpump Programming Manual User Manual

Page 89

Advertising
background image

YASKAWA TM.iQp.02 iQpump Drive Programming Manual

89

Monitor Data

The following table shows the monitor data. Monitor data can only be read.

Table 23 Monitor Data

Register No.

Contents

0020H

Drive status

Bit 0

Running 1: Running 0: Stopped

Bit 1

Reverse operation 1: Reverse operation 0: Forward operation

Bit 2

Drive startup complete 1: Completed 0: Not completed

Bit 3

Fault1: Fault

Bit 4

Data setting error1: Error

Bit 5

Multi-function digital output 1 (terminal M1 - M2) 1: ON 0: OFF

Bit 6

Multi-function digital output 2 (terminal M3 - M4) 1: ON 0: OFF

Bit 7

Not used

Bits 8 to F

Not used

0021H

Fault details

Bit 0

Overcurrent (OC) Ground fault (GF)

Bit 1

Main circuit overvoltage (OV)

Bit 2

Drive overload (OL2)

Bit 3

Drive overheat (OH1, OH2)

Bit 4

Not used

Bit 5

Fuse blown (PUF)

Bit 6

PI feedback reference lost (FbL)

Bit 7

External error (EF, EFO)

Bit 8

Hardware error (CPF)

Bit 9

Motor overload (OL1) or overtorque 1 (OL3) detected

Bit A

PG broken wire detected (PGO), Overspeed (OS), Speed deviation (DEV)

Bit B

Main circuit undervoltage (UV) detected

Bit C

Main circuit undervoltage (UV1), control power supply error (UV2), inrush prevention circuit error (UV3), power loss

Bit D

Missing output phase (LF)

Bit E

Modbus communications error (CE)

Bit F

Operator disconnected (OPR)

0022H

Data link status

Bit 0

Writing data

Bit 1

Not used

Bit 2

Not used

Bit 3

Upper and lower limit errors

Bit 4

Data integrity error

Bits 5 to F

Not used

0023H

Frequency

reference

U1-01

0024H

Output

frequency

U1-02

0025H

Output voltage

reference

U1-06

0026H

Output current U1-03

0027H

Output power

U1-08

0028H

Torque reference U1-09

0029H

Not used