43

Figure 1.31

Figure 31 Custom V/f Pattern Programming Curve

Increasing the voltage in the V/f pattern increases the available motor torque. However, when setting a custom V/f pattern, increase the

voltage gradually while monitoring the motor current, to prevent:

• Drive faults as a result of motor over-excitation

• Motor overheating or excessive vibration

Tables 5 and 6 are for 240 V class units only. For 480 V class units, multiply the voltage values by 2.

Table 5 V/f Pattern Default Settings for Drive Capacity 0.5 to 2 HP for 240 V Class

Table 6 V/f Pattern Default Settings for Drive Capacity 3 to 40 HP for 240 V Class

Parameter

No.

Name

Unit

Factory Setting

E1-03

V/f Pattern Selection

0

1

2

3

4

5

6

7

8

9

A

B

C

D

F

E1-04

Max Output Frequency

Hz

50.0

60.0

60.0

72.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

90.0 120.0 60.0

E1-05

Max Output Voltage

V

240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0

E1-06

Base Frequency

Hz

50.0

60.0

50.0

60.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

60.0

60.0

60.0

E1-07

Mid Output Frequency A

V

2.5

3.0

3.0

3.0

25.0

25.0

30.0

30.0

2.5

2.5

3.0

3.0

3.0

3.0

3.0

E1-08

Mid Output Voltage A

V

17.2

17.2

17.2

17.2

40.2

57.5

40.2

57.5

21.8

27.6

21.8

27.6

17.2

17.2

17.2

E1-09

Min Output Frequency

Hz

1.3

1.5

1.5

1.5

1.3

1.3

1.5

1.5

1.3

1.3

1.5

1.5

1.5

1.5

1.5

E1-10

Mid Output Voltage

V

10.3

10.3

10.3

10.3

9.2

10.3

9.2

10.3

12.6

14.9

12.6

17.2

10.3

10.3

10.3

E1-11

Mid Output Frequency B

Hz

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

E1-12

Mid Output Voltage B

V

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

E1-13

Base Voltage

V

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

For 480 V class units, the value is twice that of 240 V class units.

Parameter

No.

Name

Unit

Factory Setting

E1-03

V/f Pattern Selection

0

1

2

3

4

5

6

7

8

9

A

B

C

D

F

E1-04

Max. Output Frequency

Hz

50.0

60.0

60.0

72.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

90.0 120.0 60.0

E1-05

Max. Output Voltage

V

240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0 240.0

E1-06

Base Frequency

Hz

50.0

60.0

50.0

60.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

60.0

60.0

60.0

E1-07

Mid. Output Frequency A

V

2.5

3.0

3.0

3.0

25.0

25.0

30.0

30.0

2.5

2.5

3.0

3.0

3.0

3.0

3.0

E1-08

Mid. Output Voltage A

V

16.1

16.1

16.1

16.1

40.2

57.5

40.2

57.5

20.7

26.4

20.7

26.4

16.1

16.1

16.1

E1-09

Min. Output Frequency

Hz

1.3

1.5

1.5

1.5

1.3

1.3

1.5

1.5

1.3

1.3

1.5

1.5

1.5

1.5

1.5

E1-10

Mid. Output Voltage

V

8.0

8.0

8.0

8.0

6.9

8.0

6.9

8.0

10.3

12.6

10.3

14.9

8.0

8.0

8.0

E1-11

Mid Output Frequency B

Hz

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

E1-12

Mid Output Voltage B

V

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

E1-13

Base Voltage

V

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

For 480 V class units, the value is twice that of 240 V class units.

Frequency

E1-09 E1-07

E1-06

E1-04

E1-11

Max Voltage E1-05

Mid Voltage B E1-12

Mid Voltage A E1-08

Base Voltage E1-13

Min Voltage E1-10

Min

Freq

Max

Freq

Base

Freq

Mid

Freq

A

Mid

Freq B

Freq A