Yaskawa iQpump Programming Manual User Manual

Page 50

Advertising
background image

50

YASKAWA

TM.iQp.02 iQpump Drive Programming Manual

Function: Ext Baseblk N.O. (Setting: 8)
Function: Ext Baseblk N.C. (Setting: 9)

When the iQpump drive is commanded into baseblock, gating of the output transistor stops and output voltage/frequency drops to zero

(motor coasts). The iQpump drive can be forced into a baseblock state by either closing a digital input configured for Ext Baseblk N.O.

(H1-0x = 8) or opening a digital input configured for Ext Baseblk N.C. (H1-0x = 9).

When the baseblock state is removed the speed search function is used to catch the coasting motor and ramp it back to the commanded

speed.

The method of speed search, Current Detection or Speed Estimation, that is utilized when the baseblock input is removed depends on the

setting of parameter b3-01:

If b3-01 = “0: SpdsrchF Disable” or “1: SpdsrchF Enable”; Speed Estimation is used

If b3-01 = “2: SpdsrchI Disable” or “3: SpdsrchF Enable”; Current Detection is used

Figure 1.35

Figure 35 External Baseblock Characteristics

RUN Command

Baseblock Input

Speed Command

Output Frequency

Begin Speed Search

from stored Speed

Command

TIME

Advertising