Brocade Mobility RFS7000-GR Controller CLI Reference Guide

29

53-1001945-01

Common commands

2

limit (filesys) [etc2|flash|var]

Use this parameter to set the file system freespace limit. Select the
freespace limit for the following sub context:

etc2

flash

ram

limit (inodes)
[etc2|flash|var]

File system inode limit. Select the freespace limit for the following sub context:

etc2

flash

ram

limit (load) [1|15|5]

Configures the aggregate processor load. Select from the following submodes:

1 – Aggregate processor load during the previous minute.

15 – Aggregate processor load during the previous 15 minute.

5 – Aggregate processor load during the previous 5 minute.

limit (maxFDs) <0-32767>

Configures the maximum number of file descriptors. Set between 0 to 32767 file
descriptors.

limit (pkbuffers)
<0-65535>

Configures the packet buffer cache limit. Set between 0 to 65535 as the buffer
cache limit.

limit (procRAM)
< 0.0-100.0>

Defines the RAM space used by a process. Set the percentage of RAM space used by
the processor between 0 to 100.0 percent.

limit (ram) <0.0-25.0>

Configures the free space for the RAM. Configure the free space between 0.0 and
100.0 percent.

limit (routecache)
<0-65535>

Defines the IP route cache usage. Define a value between 0 - 65553.

limit (temperature) <1-8>

Sets the switch temperature sensor. Set as many as 8 temperature sensors.

period <100-30000>

Sets the diagnostic period.

<100-30000> – Configures the diagnostics period. Set a value between
100-30000 milli seconds. The default value is 1000 milliseconds.

service (diag-shell)

diag-shell

Provide diag shell access

service (encrypt)

encrypt(secret) 2 LINE

Encrypts passwords with a secret phrase using SHA256-AES256 encryption.

service (ip)

ip (igmp)

Internet Group Management Protocol

snooping

IGMP Snooping

robustness-variable
<1-7>

Robustness count

service (locator)

locator

Flash all LEDS to locate the switch visually.

service (pm)

pm

Process Monitor

Advertising