Basler Electric DGC-2020HD User Manual

Page 379

Advertising
background image

9469300990 Rev B

369

Fault

Code

String

Description

118

LO ECU SUPPLY VOLTS

Power supply voltage too low (limit 1).

119

LOLO ECU SUPPLY VOLTS

Power supply voltage too low (limit 2).

120

HI ECU SUPPLY VOLTS

Power supply voltage too high (limit 1).

121

HIHI ECU SUPPLY VOLTS

Power supply voltage too high (limit 2).

122

HI T ECU

Temperature of electronic too high (limit 1).

134

15v POSECU DEFCT

Internal electronic fault.

136

15V NEGECU DEFCT

Internal electronic fault.

137

L1 5V BUFFR TEST

Pressure-sensor fault, pressure-sensor wiring, or internal electronic
fault.

138

SENSOR PWR DEFCT

Pressure-sensor fault, pressure-sensor wiring, or internal electronic
fault.

139

L1 TE BUFFR TEST

Internal electronic fault.

140

TE BUF ECU DEFCT

Internal electronic fault.

141

AL POWER TOO HIGH

AL power too high.

142

MCR EXCEEDED 1 HR STR

AL MCR exceeded 1 hour.

143

BANK1 ECU DEFECT

Internal electronic fault.

144

BANK2 ECU DEFECT

Internal electronic fault.

145

15V GOODECU DFCT

Internal electronic fault.

147

AD TST1ECU DEFCT

Internal electronic fault.

149

AD TST2ECU DEFCT

Internal electronic fault.

151

AD TST3ECU DEFCT

Internal electronic fault.

170

MI MODULE FAIL

Module in maintenance indicator defect.

171

MI NOT ACTIVE

WI not active anymore.

172

TBO EXPIRED

TBO expired.

173

MODL WRITE LIMIT

EEPROM write limit reached.

176

AL LIFE DATA NA

No (fitting) LifeData-Backup-System is available within a delay time
after ECU Reset.

177

AL LIFE DATA INCPLT

If the ADEC has to restore the LifeData from the backup-system
and at least one checksum is wrong after the upload or the upload
is incomplete, then this failure is set.

180

AL CAN1 NODE LOST

Connection to a node on CAN 1 lost.

181

AL CAN2 NODE LOST

Connection to a node on CAN 2 lost.

182

AL CAN WRONG PARAMS

Incorrect CAN parameter values have been entered.

183

AL CAN NO PU DATA

A CAN mode is selected which the communication is initialized
aided of the PU data module. However, required PU data module is
not present or is not valid.

184

AL CAN PUDATA ERR

During attempt to copy a received PU data module to Flash
module, a program error occurred.

185

CAN LESS MAILBXS

CAN less mailboxes.

186

AL CAN1 BUS OFF

CAN controller 1 is in “Bus Off” state.

187

AL CAN1 ERR PASSV

CAN controller 1 has signaled a warning.

188

AL CAN2 BUS OFF

CAN controller 2 is in “Bus Off” state.

189

AL CAN2 ERROR PASSV

CAN controller 2 has signaled a warning.

190

AL EMU PARAM NO SUPPORT

EMU parameters are not supported.

201

SD T COOLANT

Coolant temperature-sensor defect.

DGC-2020HD

MTU Fault Codes

Advertising