9469300990 Rev B

Fault

Code

String

Description

417

SD L WATER FUEL PREFILT

Water level-sensor of fuel pre-filter defect.

420

AL L1 AUX 1

Input of Aux 1 injured limit 1.

421

AL L2 AUX 1

Input of Aux 1 injured limit 2.

428

AL L1 T AUX 1

Temperature input of Aux 1 injured limit 1.

438

LO P FUEL RAIL 2 STR

Low pressure on fuel rail 2.

439

HI P FUEL RAIL 2 STR

Hi pressure on fuel rail 2.

440

AL L1 P AUX 1

Pressure input of Aux 1 injured limit 1.

441

AL RAIL 2 LEAKAGE STR

Alarm fuel rail 2 leak detected.

442

AL L2 P AUX 1

Pressure input of Aux 1 injured limit 2.

444

SD U PDU

Sensor defect of Injector Power driver unit.

445

SD P AMBIENT AIR

Ambient air pressure-sensor defect.

448

HI P CHARGE AIR

Pressure of charge air too high (limit 1).

449

SS P CHARGE AIR

Pressure of charge air too high (limit 2).

450

SD IDLE END TRQ IN

Input of Idle/End-Torque defect

454

SS PWR RED ACT

Power Reduction is activated.

455

AL L1 AUX1 PLANT

Input of Aux 1 (plant) injured limit 1.

456

AL L2 AUX1 PLANT

Input of Aux 1 (plant) injured limit 2.

461

LO T EXHAUST EMU

Exhaust gas temperature of EMU too low (limit 1).

462

HI T COOLANT EMU

Coolant temperature of EMU injured limit 1.

463

SD AUX 2

Sensor defect on Aux 2.

464

SD P AUX 1

Analog input for pressure Aux 1 defect.

467

AL L2 T AUX 1

Temperature input of Aux 1 injured limit 2.

468

SD T AUX 1

Analog input for Temperature Aux 1 defect.

469

SD AUX 1

Analog input for Aux 1 defect.

470

SD T ECU

ECU temperature-sensor defect.

471

SD COIL CURRENT

Coil Current sensor defect.

472

AL STOP SD

Engine stop, because critical channel has sensor defect.

473

AL WIRING PWM CM2

Open load or short circuit on channel PWM_CM2.

474

AL WIRING FREQ OUT

Open load or short circuit on frequency output (FO) channel.

475

AL CR TRIG ENG ST

Released in case of an engine stop in order to trigger the crash
recorder.

476

AL CRASH REC ERR

Initial error of crash recorder.

478

AL COMB ALM YEL

Combined Alarm YELLOW (Plant).

479

AL COMB ALM RED

Combined Alarm RED (Plant).

480

AL EXT ENG PROT

External Engine Protection function active.

500

AL WIRING POM STARTER 1

A wiring fault has been detected in the connection of starter 1 of
POM.

501

AL WIRING POM STARTER 2

A wiring fault has been detected in the connection of starter 2 of
POM.

502

AL OPEN LD POM ALTRNATR

An open load on POM’s alternator output has been detected.

503

AL BATT NOT CHARGING

Battery is not being charged by alternator.

504

AL CAN POM NODE LOST

POM is missing on CAN bus.

505

AL NEW POM FOUND

New POM found.

MTU Fault Codes