Festo Кабели и принадлежности User Manual

Page 122

Advertising
background image

3. Installation

3−44

Festo P.BE−SPC200−EN en 0901d

Connection assignment of front plug X6 for the first
I/O module when operated without a field bus
module

If a field bus module is not installed, the first I/O module will
provide the following control outputs:

Outputs with control function

Pin no.

Design

1)

Address

2)

Start/Stop mode

Record Select mode

3)

1

0

Q0.0

Freely programmable

ć

2

1

Q0.1

ć

3

2

Q0.2

ć

4

3

Q0.3

MC_B

RC_B

5

4

Q0.4

MC_A

RC_A

6

5

Q0.5

SYNC_OB

ACK_B

7

6

Q0.6

SYNC_OA

ACK_A

8

7

Q0.7

READY

READY

9

24 V

24 V external supply of outputs

10

0 V

0 V external supply of outputs

1)

Designation on the module

2)

Addresses of the first installed I/O module when configured without a field bus module
(Q = output)

3)

No freely programmable I/Os are supported in this operating mode.