Festo Кабели и принадлежности User Manual

Page 138

Advertising
background image

3. Installation

3−60

Festo P.BE−SPC200−EN en 0901d

Connecting the proportional directional control
valve

The valve connection provides the power supply for the valve
and the control voltage for positioning the valve slide.

Please note
Use only the original cable type KMPYE−...Ă.

POWER

ERROR

OUT

IN

VALVE

1

2

3

4

5

6

7

Pin assignment and core colours of cable KMPYE−...

Socket for valve (MPYE) on
cable KMPYE−...

2: 0 V
3: 0 V
4: Nominal value U(s)
5: GND
6: n.c. (not connected)
7: 24 V supply for valves
1: 24 V supply for valves
n.c. (not connected)

brown
green
yellow
grey
pink
white
blue
red

2
3
4
n.c.

1
n.c.

2

1

3

4

Fig. 3/24: Valve connection