Example mode 3

Analogue nominal value specification without adjustment,
ramp

N001 M11 X100 ;Offset 100 mm

N002 M13 X3 ;Set mode 3

;Move once

N003 G01 G91 X0 FX30 ;Move relative 0 mm

;Speed ramp = 30%

N004 G61 X1 ;Fast stop

N005 M10 X30 ;Factor = 30, move

;once to analogue

;specified position

N006 G00 G90 X300 ;Move absolute

;to position 300

...

...

N020 M30 ;Program end with repeat

The speed ramp can be set with the aid of commands G01
and G02. Programming is made here for movement to be
made relatively by 0 mm (see line N003).

The speed ramp specified in this record is therefore valid
without a positioning procedure.