B. Optimizing the positioning behaviour

B−14

Festo P.BE−SPC200−EN en 0901d

Effect

Cause

Remedy

Overswing (no or minimum standstill time before MC)

1 2

Ĉ Drop in the static supply

pressure below the perĆ
mitted tolerance limit during
operation

Ĉ Mass load too high (or confiĆ

gured mass load too low)

Ĉ Overstressing (nominal

acceleration too high)

Ĉ Signal filter factor set too

high

Ĉ Gain factor set too high

Ĉ Damping factor set too low

·

Stabilize supply pressure or
carry out new system
identification with low
supply pressure
(see section B.3.1)

·

Correct mass load

·

Reduce nominal values
(especially acceleration) or
carry out dynamic
identification travel
(automatic limiting)

·

Correct parameters

·

Correct parameters

·

Correct parameters

1

Nominal position

2

Actual position

Advertising