7. Description of the commands

7−61

Festo P.BE−SPC200−EN en 0901d

Mode

Description

7

This mode serves exclusively for moving the pneumatic axis slowly and program−
controlled, providing referencing has not taken place.
Ĉ When mode 7 is activated with command G74, the axis can be moved with the

positioning commands G01 or G02.

Ĉ The speed is limited in each case to the referencing speed (see application data).
Ĉ The acceleration values are

clearly reduced.

Ĉ The status flag REF will

not be set.

Ĉ After completion of the movement in mode 7, reference travel must take place with

mode 0, 5 or 6 in accordance with the application data. Only then can the maximum
dynamics of the axis be reached again.

This mode can be used, e.g. for moving an axis manually but program−controlled into a
defined starting position, if this cannot take place automatically due to obstructions in
the positioning path.

1

Rear stop
ć here: bearing cover

2

Current position
ć starting position

for reference travel

3

Front stop
ć here: fitted

externally

4

position accepted as
reference point

5

Starting position

6

Interim reference
point: the restricted
movement starts here

1

2

3

Mode 0:

Mode 5:

Mode 6:

Mode 7:

4

5

6

Fig. 7/15: Reference travel modes for the pneumatic axis