Summary of record select mode – Festo Кабели и принадлежности User Manual

Page 211

Advertising
background image

5. Controlling the SPC200

5−25

Festo P.BE−SPC200−EN en 0901d

Summary of Record Select mode

The Record Select operating mode supports the close
coupling of the SPC200 with a higher−order PLC/IPC.

Record Select mode

Description

Prerequisites

Ĉ The program must already be saved in the program memory
Ĉ The system data must be entered in the configuration
Ĉ The Record Select mode must be set
Ĉ There must be a 1−signal at the ENABLE and STOP inputs

Operation with the control
panel

Operating functions
Ĉ Stop, Reset via menu SYSTEM CONTROL on the control panel

Operation via I/O

Operating functions
Select NC record via the RECBIT... inputs.
Ĉ Start the selected NC record via the CLK input
Ĉ Stop via the STOP input
Ĉ Program reset with 0−signal at the STOP input and rising edge

at the CLK input

Ĉ Fault acknowledgement with 1−signal at the STOP input and

rising edge at the CLK input

Advertising