4. Commissioning

4−12

Festo P.BE−SPC200−EN en 0901d

1
0

1
0

1

2

3

4

1 = 1−signal = 24 V
0 = 0−signal = 0 V

1

ENABLE input on the SPC200

2

READY output on the SPC200

3

Reaction time max. 10 ms

4

Reaction time of the SPC200:
Ĉ without stepping motor module:

max. 100 ms

Ĉ with stepping motor module:

max. 2 s

Fig. 4/2:

Time diagram of enable signal

The controller is enabled with a 1−signal, providing there are
no system faults.

A 1−signal at the ENABLE input causes the following:

ć

The current position of the axis becomes the nominal
position i.e. the axis stops in this position under closed−
loop control (controlled stop).

ć

The READY output is automatically set again, see the
following pages.

ć

If the READY output supplies a 1−signal, the program
sequence can be started or continued.