Example of program in Record Select mode

Inputs
I0.4 ... I0.0

1)

I11.9 ... I11.0

2)

NC records of the starting program

00000

N000 G00 X100.00 Y100.00

00001

N001 G00 X130.00 Y100.00

00010

N002 G01 X50.00 FX50

...

...

01000

N008 G90 X100.00 Y110.00

01001

N009 G91 X10.00 Y20.00

...

...

10000

N016 G00 X200.00 Y200.00

...

...

11111

N031 G02 X150.00 Y150.00

1)

With control via an I/O module

2)

With control via a field bus module

Sequence control takes place exclusively via a higher−order
PLC/IPC. With a rising edge at the CLK input, the signals at
the RECBIT... inputs will be accepted as NC record numbers,
acknowledged by the ACK signal and the NC record will be
processed.

Only the positioning commands (G00, G01, G02 and G74),
positioning conditions (G08, G09, G90 and G91) and comĆ
mands for setting the positioning quality class (G60, G61,
G62) will be supported.