8. Diagnosis and error treatment

8−23

Festo P.BE−SPC200−EN en 0901d

Fault class 6:

Fault in positioning task or identification travel

Fault
stage

Fault
message

Operating status / fault explanation

Eliminating faults

C

nnn01x06

Positioning timeout:
The reference position and/or the position of
the last movement task could not be reached
quickly enough (MC error)

·

Eliminate obstruction in
positioning range or check
supply pressure or increase
positioning timeout or
optimize the controller.

nnn02x06

Nominal position outside the software end
positions; the positioning process is not
started

·

Correct NC record, position
list or software end positions

nnn03x06

Non−permitted positioning task with posiĆ
tion−dependent further record switching
(G25)

·

Correct NC record or position
list (see under NC command
G25").

nnn04x06

Required speed cannot be reached

·

Correct maximum speed or
speed factor

zzz = Additional information
yy

= Fault number

x

= Axis identifier (0 = fault is not axis−related)

nnn = NC record number of the accessing NC command