Festo Кабели и принадлежности User Manual

Page 380

Advertising
background image

8. Diagnosis and error treatment

8−24

Festo P.BE−SPC200−EN en 0901d

Fault class 6:

Fault in positioning task or identification travel

Fault
stage

Eliminating faults

Operating status / fault explanation

Fault
message

C

ssz05x06

Fault in identification travel
ss = Service information specifies the

identification step in which the fault
occurred.

z

= Fault type (see following description)

(See following description)

ss0:

Fault in pre−calculating the control
parameters (x10, x50, x90)
or
timeout (x20, X60, XA0)

·

Check controller, axis and
application data

ss1:

The system identification was aborted
with Stop. The stop can be triggered
by the user or by a system fault.

·

Check I/O coupling;

·

Check fault stack (with
WinPisa) and if necessary
eliminate the cause of the
fault.

ss2:

No sensible parameters were found
during system identification

·

Check controller, axis and
application data

·

Check general conditions

Ĉ Construction susceptible to

vibration?

Ĉ Supply pressure stable?
Ĉ Is the driver of the measurĆ

ing system fastened corĆ
rectly, etc?

ss4:

A fault occurred when the original
parametrizing was restored

Check controller, axis and
application data

ss8:

A fault occurred when the identifica−
tion step was initialized

Check controller, axis and
application data

zzz = Additional information
yy = Fault number
x

= Axis identifier (0 = fault is not axis−related)

Advertising