2 start/stop mode, Start/stop mode – Festo Кабели и принадлежности User Manual

Page 195

Advertising
background image

5. Controlling the SPC200

5−9

Festo P.BE−SPC200−EN en 0901d

5.2

Start/Stop mode

Start/Stop mode

In Start/Stop mode the SPC200 can control positioning
tasks independently. The following are available in this
operating mode if an I/O module is used:

ć

five freely programmable inputs

ć

three freely programmable outputs

ć

all NC commands.

With each further I/O module, a further ten freely programĆ
mable inputs and eight freely programmable outputs are
available. For special I/O functions directly on the axis, I/Os
can be made available via modules on the axis interface
string.

The sequence of programs can be controlled in Start/Stop
mode via digital I/Os. The command Programmed Stop (M00)
is available for loose coupling with a higher−order PLC/IPC.
With this command you can synchronize the program seĆ
quence of the SPC200, e.g. with externally controlled proĆ
cesses.

The following diagram shows the I/O circuitry in case you
wish to trigger the operating functions Start, Stop and Enable
via an external control panel. Instead of a control panel you
can also use a higher−order PLC/IPC for controlling.