7. Description of the commands
7−82
Festo P.BE−SPC200−EN en 0901d
L
Access sub−program (load subroutine)
ć permitted in operating modes: Start/Stop
Nn L<Program number>
<Program
b
n
Program number
n = 0 ... 99
number>
Rn
Program number saved in register Rn
n = 0 ... 99
Effect
Accesses the specified program as subroutine.
Example
See below
Remark
The program number can be specified directly (n) or indirectly via a register (Rn).
Maximum nesting depth = 4.
Example
Palletizing
1
Distance between
rows
2
Positions
0 mm
200 mm
250 mm
1
2
Fig. 7/19: Palletizing