Festo Кабели и принадлежности User Manual

Page 259

Advertising
background image

6. Operating the SPC200 with the control panel

6−47

Festo P.BE−SPC200−EN en 0901d

Menu SYSTEM CONTROL

SYSTEM CONTROL

RESET SYSTEM ?

Reset system
The SPC200 is reset to the status it was in when it was switched on.
A program reset and a hardware recognition are carried out here and
the axis interface string is re−initialized. This procedure can take a
certain amount of time, depending on the system configuration used.

SYSTEM CONTROL

RESET PROGRAMS ?

Reset program
Prerequisites:
Ĉ there must be a 1−signal at the ENABLE input
This will have the following effects:
Ĉ the NC record pointer is reset to 0
Ĉ the pre−settings G90 and G02 (speed and acceleration values and

workpiece mass in initial state), as well as the positioning quality
class set in the application data become valid

Ĉ the nominal value input is switched off (M12)
Ĉ all settings undertaken with M10, M11, M13 or M14 are reset to the

defined standard values (parameter set for the axis, Nominal value
specification" tab)

Ĉ pre−switch off values defined with G25 are reset again
Ĉ direct control of the valve voltage (M39) is deactivated
Ĉ all settings undertaken with M40 and M41 are reset to the standard

values

Ĉ all freely programmable outputs and the SYNC outputs are reset
Ĉ the set starting programs are made available
Ĉ any faults are acknowledged.

SYSTEM CONTROL

RESET ERROR ?

Reset fault
Prerequisites:
Ĉ there must be a 1−signal at the ENABLE input
With this command the fault code is reset to 0.

SYSTEM CONTROL

RESET DATA ?

Reset all data to the status as at delivery
With this command all data are reset to the status as at delivery.
All user data will be lost.

Advertising