Festo Кабели и принадлежности User Manual

Page 179

Advertising
background image

4. Commissioning

4−35

Festo P.BE−SPC200−EN en 0901d

Identification

Meaning

STATIC

Static identification

DYNAMIC1

Dynamic identification with workpiece

*)

DYNAMIC2

Dynamic identification without workpiece

*)

*)

Workpiece must be removed or added

8. Press the Enter button in order to save the identification

travel.

The identification travel takes a certain amount of time.
During identification progress is indicated as a per cent
value. After successful identification travel the message OK is
shown, e.g.:

IDENTIFICATION

X: DYNAMIC1 OK

You can return to the basic setting by pressing the ESC
button several times.

If system identification is not successful:

·

Check the layout, the installation as well as the axis and
application data of the relevant axis. Then carry out
identification again.

Step 4:

Calibrate the measuring system
(optional,Ăonly with WinPISA)

From operating system version 4.82 onwards, the calibration
function requires WinPISA version 4.41 or higher.

Calibration compensates for system−specific tolerances
which may occur when the actual position is ascertained.
In this way the electrically ascertained position values are
adapted to the actual values.

Carry out calibration if you wish to save or improve the
absolute positioning accuracy.

Non−compatible
as from

OS 4.82

Advertising