5. Controlling the SPC200

5−15

Festo P.BE−SPC200−EN en 0901d

Programmed Stop

Synchronization of the SPC200 with externally controlled
processes is supported by the Programmed Stop (command
M00). For this purpose, the SPC200 provides separate control
I/Os for programs A and B.

The relevant program will be stopped with the Programmed
Stop (command M00). If there is a 1−signal at the relevant
SYNC input (SYNC_IA or SYNC_IB), the SPC200 will indicates
the stop status of the program by setting the appropriate
SYNC output (SYNC_OA or SYNC_OB). Externally controlled
processes can then run.

1
0

1
0

1
0

SYNC_IA/IB

SYNC_OA/OB

MC_A/B

M00

M00

G00/G01/G02

G00/G01/G02

1

1

2

2

3

3

1

Externally controlled process

2

Programmed Stop

3

Program sequence

Fig. 5/6:

Time behaviour with a Programmed Stop

If there is a negative edge at the SYNC input, the SYNC output
will be reset and the program will be processed further. The
continuation of the program sequence is represented in
Fig. 5/5 with the aid of the MC signal.