Mass load – Festo Кабели и принадлежности User Manual

Page 420

Advertising
background image

A. Notes on installing the pneumatic components

A−28

Festo P.BE−SPC200−EN en 0901d

Please note
Observe the operating instructions for the DSMI−... .
Make sure that:

Ĉ the permitted lateral force

Ĉ the permitted longitudinal force and

Ĉ the maximum permitted swivel frequencies are

observed.

·

Make sure that the cushioning plate is fitted on the stop
lever of the DSMI−... .

·

Recommendation: Limit the swivel range by means of
shock absorbers. In this way you can avoid damage in the
event of operating and system faults.

·

In order to earth the device, connect the earth connection
of the DSMI−... and the earth connection of the axis interĆ
face with an earth strap or an earth cable (cross−sectional
area min. 2.5 mm

2

, length max. 0.5 m; see Fig. A/16).

Mass load

In conjunction with the SPC200, operation of the DSMI−... is
regulated electronically. Special mass moments of inertia
therefore apply (see chapter 3.2.9).

Please note
Make sure that the permitted mass moment of inertia is
observed during operation. The mass moment of inertia
must not change during the movement.

·

Fit the mass load free of play.

·

Avoid a mass load with unfavourable internal vibrations.

Advertising