7. Description of the commands

7−10

Festo P.BE−SPC200−EN en 0901d

In autonomous operation the program is processed indepenĆ
dently for each work station. Each work station can be conĆ
trolled independently of the other by means of the freely proĆ
grammable I/Os (Start/Stop operation) or by the command
I/Os (Record Select operation).

Please observe the following when using parallel program
processing in autonomous operation:

ć

Starting programs must not be accessed as
sub−programs.

ć

Sub−programs, which contain positioning commands,
may only be used by one starting program.

7.1.2

Program organisation

When programming for the SPC200 you can:

ć

create up to 100 NC programs in the SPC200 with a maxiĆ
mum total of 2000 NC records

ć

enter up to 1000 NC records (i.e. 1000 program lines) in
one single program

ć

access each NC program as a sub−program. Four nested
sub−program calls are therefore possible.