Festo Кабели и принадлежности User Manual

Page 405

Advertising
background image

A. Notes on installing the pneumatic components

A−13

Festo P.BE−SPC200−EN en 0901d

Installation instructions for standard cylinder DNC−...

ć

Any mounting position is permitted (horizontal, vertical or
diagonal).

·

Note that in conjunction with the SPC200, the complete
stroke of the drive must not be used.

Permitted work stroke = stroke length minus stroke
reduction

On each side of the drive positioning must

not take place in

the range of the stroke reduction (see also chapter 3.4).

ć

The best possible positioning behaviour can be
achieved if you use only 80 % of the stroke length of
the drive, symmetrically to the two end positions.

ć

If demands placed on the positioning behaviour are
only slight, observe at least the following stroke reĆ
ductions in both end positions:

Piston j [mm]

32

40

50

63

80

Stroke reductionper end position
with pneumatic cushioning [mm]

10

10

15

15

15

Stroke reduction per end position
with PPV cushioning [mm]

25

25

30

30

35

·

Drives with adjustable end position cushioning (PPV): In
order to use the end position cushioning as minimum
stop protection, tighten completely the adjusting screws
for the internal end position cushioning.

·

Recommendation: Limit the positioning range by shock
absorbers, also in the case of a cylinder with adjustable
cushioning. In this way you can avoid damage in the
event of operating and system faults.

Advertising