C.4.3, C−30 – Festo Кабели и принадлежности User Manual

Page 476

Advertising
background image

C. Technical appendix

C−30

Festo P.BE−SPC200−EN en 0901d

C.4.3

Technical specifications of the I/O function module type SPC−FIO−...

Type

SPC−FIO−2E/2A−M8

1)

(PNP)

Temperature range
Ĉ Operation
Ĉ Storage/transport

− 5 ... + 50 °C
− 20 ... + 70 °C

Weight

42 g

Relative humidity

95 %, non−condensing

Protection class as per EN 60529
plug connectors inserted or fitted with
protective cap

IP65

CE symbol (declaration of conformity)
è

www.festo.com

In accordance with EU EMC Directive

Vibration and shock
Ĉ Vibration

Ĉ Shock

Tested as per DIN/IEC 68 part 2−6:
± 30 g at 11 ms duration; 5 shocks per direction
Tested as per DIN/IEC 68 part 2−27:
± 30 g at 11 ms duration; 5 shocks per direction

Digital inputs
Ĉ Design
Ĉ Protection against incorrect polarity
Ĉ Logic level:

ON
OFF

Ĉ Reference potential
Ĉ Current consumption (at 24 V)

(input current from sensor to input)

Ĉ Response delay (at 24 V)

2 inputs as per IEC 1131−2 type 2 inputs
24 V DC, positive switch. PNP, status display by LED
− 30 ... + 30 V
> 11 V
< 5 V
0 V
At logical 1" typ. 7 mA

Typ. 3 ms

Sensor supply

2)

V

D

24 V

± 25 %

Max. 0.5 A (electronic short−circuit protection)

Digital outputs
Ĉ Design
Ĉ Load capacity per output

1)

Ĉ Electronic fuse (short circuit, overload)

Trigger current
Electrical isolation

2 outp. as per IEC 1131−2; 24 V DC positive switching
250 mA

Min. >500 mA
None

Internal current consumpt. of electronics

2)

< 40 mA

1)

External load voltage supply type SPC−AIF−SUP−24V required

2)

Is provided by module SPC200−PWR−AIF (internal electronics, pin 2)

Advertising