A. Notes on installing the pneumatic components

A−35

Festo P.BE−SPC200−EN en 0901d

Installation instructions for standard cylinder
typeĂDNCI−...

ć

Any mounting position is permitted (horizontal, vertical or
diagonal)

·

Note that in conjunction with the SPC200, the complete
stroke of the drive must not be used.

Permitted work stroke = stroke length minus stroke
reduction

On each side of the drive positioning must

not take place in

the range of the stroke reduction (see also chapter 3.4).

ć

The best possible positioning behaviour can be
achieved if you use only 80 % of the stroke length of
the drive, symmetrically to the two end positions.

ć

If demands placed on the positioning behaviour are
only slight, observe at least the following stroke reĆ
ductions in both end positions:

Piston j [mm]

32

40

50

63

Stroke reduction per end position [mm]

10

10

15

15

·

Recommendation: Limit the movement range by means of
shock absorbers. In this way you can avoid damage in the
event of operating and system faults.

·

Arrange the tubing between the valve (MPYE−5−...) and the
drive (DNCI−...) symmetrically and as short as possible.
Maximum tubing length = cylinder stroke length + 50 mm.

·

Lubricate the external guide at suitable maintenance inĆ
tervals (be sure to note manufacturer specifications).

·

Use only fastening elements which can permanently resist
the acceleration forces.