Festo Кабели и принадлежности User Manual

Page 332

Advertising
background image

7. Description of the commands

7−66

Festo P.BE−SPC200−EN en 0901d

M00

Programmed stop

ć permitted in operating modes: Start/Stop

Nn M00

Effect

The program sequence will be stopped with command M00 and continued when a
synchronization signal is received. In the operating mode Start/Stop a negative
edge at input SYNC_IA/IB will be interpreted as a synchronization signal.

Example

N005 M00

N006 G00 X100

;Wait for SYNC signal
;Move to position X100

Remark

In Start/Stop mode you can synchronize with this command the program sequence
with other devices.

1
0

1
0

1
0

SYNC_IA/IB

SYNC_OA/OB

MC_A/B

M00

M00

G00/G01/G02

G00/G01/G02

1

1

3

3

2

2

1

Externally controlled process

2

Programmed stop

3

Program sequence

Fig. 7/17: Programmed stop