Festo Кабели и принадлежности User Manual

Page 184

Advertising
background image

4. Commissioning

4−40

Festo P.BE−SPC200−EN en 0901d

2. Press the Enter button in order to select the command.

The current operating mode will then be displayed, e.g.:

OPERATING MODE

RECORD SELECT

3. Select the operating mode START/STOP and press the

Enter button. The operating mode then becomes
effective.

OPERATING MODE

START/STOP

You can return to the basic setting by pressing the ESC
button several times.

You can test the program in single steps as follows:

Necessary control signals:
1−signal at ENABLE, STOP and READY.

1. Select the submenu SYSTEM in the menu TEST/DIAG. and

press the Enter button. The command SINGLE STEP in the
submenu SYSTEM (SYS.) will then be displayed.

TEST/DIAG. SYS.

SINGLE STEP >

2. Press the Enter button in order to select the command.

SINGLE STEP

P00

Advertising