Ascertain by formula

Proceed as follows:

1. Calculate the maximum current consumption of the interĆ

nal electronics, the connected modules and measuring
systems (I

1

) as well as the load supply for outputs, field

devices and proportional directional control valves (I

2

)

(see also chapter 3.5.1).

2. Ascertain the lowest voltage to be expected during operĆ

ation (V

Bmin

) on the power unit. Take the following into

account:

·

the load dependency of the power unit

·

the fluctuations in the primary mains voltage

·

the operating temperature of the devices.

3. Enter the values in the relevant formula. The equivalent

circuit diagram as well as the example explain the correlaĆ
tions.