4. Commissioning

4−36

Festo P.BE−SPC200−EN en 0901d

Step 5:

Move the axis by means of the control
panel (optional)

Necessary control signals:
1−signal at ENABLE, STOP and READY.

With the command JOG AXIS in the menu TEST/DIAG. you
can move the axis manually. Proceed as follows:

1. Select the submenu AXIS in the menu TEST/DIAG. and

press the Enter button.

TEST/DIAG. AXIS

X:

2. The cursor is positioned on the axis identifier. Select the

desired axis with the buttons

vV (here X) and press

the Enter button. The command JOG AXIS in the submenu
AXIS will then be displayed.

TEST/DIAG. AXIS

JOG AXIS >

3. Press the Enter button in order to select the command.

The previously selected axis and the current positioning
mode will then be displayed.

JOG AXIS

X: CONT

4. Select the desired positioning mode with

vV.

Meaning:

Positioning mode

Meaning

CONT

Position continuously

STEP

Position in steps twice the set
positioning tolerance

Advertising