Festo Кабели и принадлежности User Manual

Page 345

Advertising
background image

7. Description of the commands

7−79

Festo P.BE−SPC200−EN en 0901d

Valve positionĆ
ing value [%]

Positioning
signal

1)

Valve voltage
[V]

Effect

ć

ć

2)

ć

2)

Proportional directional
control valve pressurizes

1

−0.98

9.9

control valve pressurizes
connection 4
} Effect of force in the

2

−0.96

9.8

} Effect of force in the
direction of the measuring
system ero point (smaller

...

...

...

system zero point (smaller
positioning values)

49

−0.02

5.1

p

g

Mid

iti

f th

l

50

0.00

5.0

Mid−position range of the valve
(covered), flow blocked

51

0.02

4.9

(

)

...

...

...

Proportional directional
control valve pressurizes

98

0.96

0,2

control valve pressurizes
connection 2
} Effect of force in the

99

0.98

0.1

} Effect of force in the
direction away from the
measuring system zero point

ć

ć

ć

measuring system zero point
(larger positioning values)

1) Standardized valve positioning signal

2)

Specification not possible

The valve voltage can be calculated as follows:

Formula

V

valve

+ 10 <

ǒ

1

* n

100

Ǔ

V

valve

= valve voltage in [V]

n

= valve positioning value in [%]

Advertising