Explanation of all i/o signals in start/stop mode, Inputs – Festo Кабели и принадлежности User Manual

Page 197

Advertising
background image

5. Controlling the SPC200

5−11

Festo P.BE−SPC200−EN en 0901d

5.2.1

Explanation of all I/O signals in Start/Stop mode

The connection assignment and I/O addresses of the I/O
modules can be found in chapter 3.5.3, field bus addresses in
the manual for the field bus module.

Inputs

Function

Description

SYNC_IB

Synchronization input for program B
(like SYNC_IA, but for program B)

SYNC_IA

Synchronization input for program A
This input supports synchronization of the SPC200 with external devices (e.g.
PLC/IPC). With a Programmed Stop (command M00) the SPC200 waits for a falĆ
ling edge at this input before it processes the next NC record (see Fig. 5/6).

STOP

Stop program sequence
A falling edge at this input causes:
Ĉ the program sequence and the axes to be stopped.
Ĉ Depending on the parameterisation, the axis is stopped (controlled stop):

Ĉ The position at the time of the stop signal becomes the setpoint position

(d f

lt) Aft

t

d till th

i

b

k t thi

iti

New feature
as from
OS 4.93

(default). After standstill, the axis runs back to this position.

Ĉ The current position at standstill becomes the setpoint position.

This function is only available as from firmware version 4.93 in combination
with WinPISA as from version 4.51.

If there is a 0−signal, a Program Reset can be triggered by a rising edge at the
START input (see under START input).
The program sequence is continued by:
1. a 1−signal at this input
2. a new start signal (Start on the control panel or a rising edge at the START

input).

Advertising