116 • Using Setup Mode

EAGLE 2 Operator’s Manual

5. Press and release POWER ENTER RESET. The alarm point or alarm

operation (oxygen only) will begin to flash.

6. Use AIR ▲ YES and RANGE ▼ SHIFT to adjust the alarm point or

alarm operation (oxygen only) to the desired setting. Keep the following
in mind:

The low alarm cannot be set higher than the high alarm and the high
alarm cannot be set lower than the low alarm.

Any alarm setting can be turned off by adjusting it to its lowest
setting. The setting will be displayed as OFF.

In addition to setting the oxygen alarm points, you can also select one
of the following operation modes: low alarm decreasing and high
alarm increasing (FALLING AND RISING); low and high alarm
decreasing (BOTH FALLING); low and high alarm increasing
(BOTH RISING). The factory setting is FALLING AND RISING.

In order to appropriately set the calibration gas value during a
calibration, the low alarm setting must be lower than the desired
calibration value.

7. If you want to continue with the change, press and release POWER

ENTER RESET to accept the setting.

If you want to exit this screen without saving any change to the alarms,
press and release DISPLAY ADJUST NO until you return to the Change
Alarm Point Settings Screen.

8. Repeat Step 4- Step 7 for any additional changes you want to make.

9. When you are done making changes, use RANGE ▼ SHIFT to move the

cursor next to END.

10. Press and release POWER ENTER RESET to save the new settings and

return to the Change Alarm Point Settings Screen.

11. Use RANGE ▼ SHIFT to move the cursor next to END.

12. Press and release POWER ENTER RESET to return to the main menu.

Updating the Alarm Latching Setting

With ALARM LATCHING set to LATCHING (factory setting), the
EAGLE 2 remains in alarm condition until the alarm condition passes and the
POWER ENTER RESET button is pressed.

With ALARM LATCHING set to SELF RESET, the EAGLE 2
automatically resets an alarm when the alarm condition passes.