Table 18: ESM-01 Sensor Specifications

Description

Table 18 above lists the available ESM-01 sensors. The ESM-01 is a smart
sensor that stores sensor parameters including the target gas, detection range,
alarm points, and calibration settings in its memory. So a sensor can be
calibrated at the factory and shipped as a replacement sensor without the need
to calibrate the sensor when it is installed as long as it is installed during the
sensor’s valid calibration period which is typically 3 months. In addition, you
can change an existing ESM-01 channel from one type of ESM-01 sensor to
another and the EAGLE 2 will automatically load all the sensor parameters
and configure the ESM-01 channel for the new sensor without the need to
enter CONFIGURE CHANNELS or CONFIGURE GASES in Setup Mode.

Target Gas

Detection

Range (ppm)

Reading

Increment

Alarm 1

Factory

Setting

Alarm 2

Factory

Setting

STEL

(ppm)

TWA

(ppm)

Ammonia

(NH

3

)

0 - 75.0

0.5 ppm

12.0 ppm

25.0 ppm

35

25

Arsine

(AsH

3

)

0 - 1.50

0.01 ppm

0.20 ppm

0.50 ppm

OFF

OFF

Chlorine

(Cl

2

)

0-3.00

0.02 ppm

0.50 ppm

1.50 ppm

1.00

0.50

Hydrogen

Cyanide

(HCN)

0 - 15.0

0.1 ppm

3.00 ppm

5.00 ppm

4.7

OFF

Phosphine

(PH

3

)

0 - 1.00

0.01 ppm

0.10 ppm

0.30 ppm

1.00

0.30

Sulphur

Dioxide

(SO

2

)

0 - 6.00

0.05 ppm

1.00 ppm

2.00 ppm

1.00

0.50