278 • Bar Hole Testing

EAGLE 2 Operator’s Manual

• Press and release the DISPLAY ADJUST NO button. The

display will now indicate “FRESH AIR PURGE . . .” below the
oxygen reading and the purge time will begin counting down
from 30 seconds in the lower right corner of the display.

• After 15 seconds of sampling, if the CH

4

reading is less than 5

vol%, the CH

4

channel will automatically begin displaying in

the units you selected earlier. Since performing a fresh air
purge draws fresh air, the display units should always switch
to the previously selected units. If you selected the methane
channel to be displayed in vol%, then after 15 seconds, the
reading will remain in vol%.

• When the purge is complete, the screen will return to the initial

Bar Hole Mode screen.

7. If other bar holes will be tested, proceed to the next bar hole and

repeat Step 3 - Step 6.

8. To cancel a bar hole measurement or fresh air purge that is in

progress, press and release the DISPLAY ADJUST NO button.

9. To exit Bar Hole Mode and return to the Mode Select Screen at any

time, press and hold the RANGE ▼ SHIFT button for 5 seconds.

Turning Off the EAGLE 2, Bar Hole Mode

1. Press and hold the POWER ENTER button.

2. The unit will initiate a bar hole measurement. Keep holding the

POWER ENTER button. The buzzer will sound and the LCD back
light will flash for about five seconds.

3. Release the button when GOODBYE appears on the display. When

GOODBYE disappears and the backlight turns off, the unit is off.

BAR HOLE MODE

CH4 0 vol%
OXY 20.9 vol%

FRESH AIR PURGE...

30 SEC

BAR HOLE MODE

CH4 0 vol%
OXY 20.9 vol%
ENTER: MEASURE
ADJUST: PURGE